H5000 5/10/15KWh
--Battery capacity 5000wh |Lifecycles 3000 times+
--5000W AC Pure Sine Wave Inverter (Peak power 10000VA)
--LCD Screen Design
--8 PROTECTIONS | Over Load / Over Current / short Circuit High Temperature RoHs Certificate / Low Voltage / Fireproof
--5 year warranty
Feature:
1. Built - in LiFePO4 Battery cells. Large capacity, long cycle life, high safety, environmental protection.
2. High power inverter to meet the household daily electrical use.
3. Multiple electrical protection, safe and reliable, adopting LFP cells, safe and stable.
4. Provides the UPS function to ensure stable operation of critical loads.
5. Adopt full digital voltage and current double closed - loop control and advanced SPWM technology to output pure sine wave.
6. Multiple working modes: The inverter has a variety of working modes. whether it is used for main power supply in the area without electricity or backup power supply in the area with unstable power to deal with sudden power failure, the system can respond flexibly.
7. Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging.




| MODE | H5000A / E | H10000A / E | H15000A / E |
|---|---|---|---|
| INVERTER OUTPUT | |||
| Rated Output Power / Peak Power | 5000W / 7500W | 5000W / 7500W | 10000W / 15000W |
| Rated output voltage | 120Vac (100 / 105 / 110Vac Settable) / 230Vac (200 / 208 / 220 / 240Vac Settable) | 120Vac (100 / 105 / 110Vac Settable) / 230Vac (200 / 208 / 220 / 240Vac Settable) | 120Vac (single phase L + N + PE) |
| Rated AC Frequency | 50Hz ± 0.3Hz / 60Hz ± 0.3Hz | ||
| Waveform | Pure Sine Wave | ||
| Conversion time (bypass and inverter) | 10ms (Typical value) | ||
| Overload protection | (102% < load < 110%) ± 10%: reporting error and turn off the output after 5 minutes; (110% < load < 125%) ± 10%: reporting error and turn off the output after 10 seconds; Load > 125% ± 10%: reporting error and turn off the output after 5 seconds | ||
| BATTERY | |||
| Battery type | LiFePO4 | LiFePO4 | LiFePO4 |
| Lifecycles | 4000 times + | 4000 times + | 4000 times + |
| Nominal capacity | 100Ah / 5.12KWh | 200Ah / 10.24Wh | 280Ah / 14.33KWh |
| Nominal Voltage | 51.2Vdc | 51.2Vdc | 51.2Vdc |
| Battery Working Voltage Range | 44.8 - 57.6Vdc | 44.8 - 57.6Vdc | 44.8 - 57.6Vdc |
| Max.MPPT Charging Current | 80A | 80A | 200A |
| Max.Mains/Generator Charging Current | 40A / 60A | 40A / 60A | 120A |
| Max.Hybrid Charging Current | 80A | 80A | 200A |
| PV INPUT | |||
| Num. of MPP Trackers | 1 | 1 | 2 |
| Max.PV array power | 5000W | 5000W | 11000W / 5500W + 5500W |
| Max.input current | 22A | 22A | 22A / 22A + 22A |
| Max.Voltage of Open Circuit | 500 Vdc | 500 Vdc | 500 Vdc / 500Vdc + 500Vdc |
| MPPT Voltage Range | 120 - 450Vdc | 120 - 450Vdc | 125 - 425Vdc |
| MAINS / GENERATOR INPUT | |||
| Input Voltage Range | (90Vac - 140Vac) ± 2% / (170Vac - 280Vac) ± 2% | (90Vac - 140Vac) ± 2% / (170Vac - 280Vac) ± 2% | 90 - 140Vac / 90 - 275Vac |
| Frequency Range | 50 / 60Hz | ||
| Bypass Overload Current | 63A / 40A | 63A / 40A | 63A |
| EFFICIENCY | |||
| MPPT Tracking Efficiency | 99.90% | ||
| Max. Battery Inverter Efficiency | 92% | ||
| Authentication specification | |||
| Safety | CETL(UL 1741 CSA 22.2 NO.107.1) / CE(IEC62109 - 1) | CETL(UL 1741 CSA 22.2 NO.107.1) / CE(IEC62109 - 1) | CETL(UL 1741 / CSA 22.2 NO.107.1) / CE(IEC62109 - 1) / CE(IEC62109 - 2) |
| EMC | EN61000 | EN61000 | EN61000 - 6 - 1, EN61000 - 6 - 3, FCC 15 class B |
| Operation temperature range | -10°C to 55°C | -10°C to 55°C | -10°C to 55°C, >45°C derated |
| Storage temperature range | -25°C - 60°C | ||
| Humidity range | 5% to 95% (Conformal coating protection) | ||
| Noise | <60dB | ||
| Cooling Method | Forced cooling with adjustable air speed | Internal Fan | |
| Weight | 65Kg | 112.5Kg | 138Kg |
| Size (L * W * H) | 516×320×726mm | 692×346×1004mm | 692×346×1004mm |